OXY-LC Interface Board
Contact our experienced engineers to discuss your application needs.
Details
- Provides the electronics necessary to power and control PSTβs range of zirconia (ZrO2) sensors
- Built in pressure sensor for barometric pressure compensation
- Interface mounted screw terminals for easy wiring with reverse voltage and transient overvoltage
The OXY-LC Oxygen Sensor Interface Electronics is designed to supply power and manage the operation of SSTβs range of zirconia (ZrOβ) oxygen sensors.
It supports multiple user-configurable output options, including RS485, PWM, 0β10 VDC, and 4β20 mA. Among these, the RS485 Modbus RTU protocol provides significant advantages, most notably full control over sensor operation and access to comprehensive data such as sensor diagnostics, barometric pressure, and internal pressure sensor temperature.
The interface features adaptive software filtering, which enables fast response times while maintaining a stable oxygen output. Additionally, it delivers a highly accurate, linear output signal across all supported zirconia oxygen sensors.
An integrated pressure sensor enables barometric pressure compensation, and interface-mounted screw terminals facilitate straightforward wiring. Built-in protection includes reverse voltage and transient overvoltage safeguards.
It supports multiple user-configurable output options, including RS485, PWM, 0β10 VDC, and 4β20 mA. Among these, the RS485 Modbus RTU protocol provides significant advantages, most notably full control over sensor operation and access to comprehensive data such as sensor diagnostics, barometric pressure, and internal pressure sensor temperature.
The interface features adaptive software filtering, which enables fast response times while maintaining a stable oxygen output. Additionally, it delivers a highly accurate, linear output signal across all supported zirconia oxygen sensors.
An integrated pressure sensor enables barometric pressure compensation, and interface-mounted screw terminals facilitate straightforward wiring. Built-in protection includes reverse voltage and transient overvoltage safeguards.
Operating pressure limits
260β1260mbar absolute * Sensor and interface for correct barometric pressure compensation.
Oxygen range (analogue output)
0.12β25% O2 or 0.12β100% O2
Supply voltage
RS485 variant: 8β28VDC - Analogue variants: 20β28VDC
Supply current
600mA max. at 24VDC - 600mA max. at 24VDC
Digital output
RS485 (Modbus RTU) or PWM