LuminOx
Contact our experienced engineers to discuss your application needs.
Details
- Engineered for full immersion into the gas sample stream
- Minimal cross-sensitivity to other gases
- Fully RoHS & REACH compliant
- Operates reliably in both vacuum conditions and high oxygen concentrations
- Direct interface with microcontrollers, including Arduino and Raspberry Pi
- Outputs include oxygen concentration (%), partial pressure Oâ‚‚ (ppOâ‚‚), temperature, and barometric pressure
- Typical response time (T90) under 30 seconds
- Solid-state, non-depleting luminescence sensing technology
- Fast turnaround available for sample units
- Test software provided for evaluation and integration
- Access to SST’s in-house engineering support for application and validation guidanceSensor board sold separately
Manufactured by SST, the LuminOx series comprises factory-calibrated optical oxygen sensors that employ a luminescence-based technique to accurately measure gaseous oxygen levels with high efficiency. The standard LuminOx sensor is designed for full immersion in the gas sample, providing reliable performance across a wide range of conditions—from vacuum to elevated oxygen concentrations. Its engineered design minimizes cross-sensitivity to other gases, making it well-suited for mixed or fluctuating gas environments. Each sensor integrates SST’s patented luminescence quenching technology, delivering extended operational life without the degradation common to galvanic or electrochemical alternatives. The non-depleting measurement principle ensures sustained accuracy with low power requirements.
Built-in temperature and barometric pressure compensation allows the sensor to output corrected readings directly, streamlining system integration via a UART interface—no external signal conditioning needed. LuminOx sensors are solid-state and free from hazardous substances such as lead and liquid electrolytes, meeting RoHS and REACH compliance. With fast availability and dedicated technical support, LuminOx provides a reliable and adaptable solution for precise oxygen sensing across diverse applications.
Built-in temperature and barometric pressure compensation allows the sensor to output corrected readings directly, streamlining system integration via a UART interface—no external signal conditioning needed. LuminOx sensors are solid-state and free from hazardous substances such as lead and liquid electrolytes, meeting RoHS and REACH compliance. With fast availability and dedicated technical support, LuminOx provides a reliable and adaptable solution for precise oxygen sensing across diverse applications.
Supply voltage (Vs)
4.5—5.5VDC
Oxygen range
0—25% O2
Barometric pressure range
500—1200mbar
Output Type
3.3V TTL level UART
Operating Temperature
-30°C to +60°C
Datasheets
Evaluation Kit
User Guide
Application Notes
3D Models
Accreditation & Compliance